Gulf Union Ozone supplies a complete range of ATEX and IECEx certified cable glands, hazardous-area conduit systems, cable cleats and junction boxes for Saudi Arabia oil & gas, petrochemical, refining and industrial electrical installations. Our portfolio covers Ex d (flameproof) and Ex e (increased safety) cable glands in nickel-plated brass, 316 stainless and aluminium for Zone 1 and Zone 2 classified areas to Saudi Aramco SAES-B-006 and SAES-B-068 requirements. Armoured cable glands for SWA, DSTA and STA cables are stocked in sizes M16 to M100, rated IP66/IP68 for LV and HV power cables on Saudi industrial projects. ATEX Zone 1 and Zone 2 conduit fittings — elbows, unions, sealing fittings and male adaptors — are available in galvanised steel, aluminium and stainless steel with BSP, NPT and metric thread options. Cable cleats to IEC 61914, rated for short-circuit forces up to 63 kA peak, cover single-core and trefoil three-core HV cable runs at Saudi substation and switchgear installations. GRP and stainless ATEX junction boxes (Ex d and Ex e, 4–60 way) and full ranges of sealing accessories are stocked for same-day dispatch from Jeddah. All products carry IECEx certificates accepted as equivalent to ATEX by SASO and Saudi Aramco. ISO 9001:2015 certified, CR 4030570569.

Gulf Union Ozone carries six hazardous-area cable management product families for Saudi Arabia oil & gas, petrochemical and industrial electrical projects, with ATEX and IECEx certification and IEC 60079-14 installation compliance documentation for every supply.
Ex d (flameproof) and Ex e (increased safety) cable glands in nickel-plated brass, stainless 316 and aluminium for Zone 1 and Zone 2 hazardous areas on Saudi Aramco and SABIC plants; IP66/IP68 rated. Thread forms include metric (M16–M100), BSP and NPT; IECEx certified for temperature classes T1–T6; cable OD ranges from 5 mm up to 68 mm; installation per IEC 60079-14.
SWA, DSTA and STA armoured cable glands in sizes M16–M100 with compression armour clamp; IP66/IP68, suitable for HV and LV power cables on Saudi industrial projects. Armour clamp grips SWA, DSTA and STA armour wires positively without cutting; inner seal and outer seal compress independently to handle wide tolerances on armoured cable sheath dimensions; earth continuity through the gland body.
ATEX Zone 1 and Zone 2 conduit fittings — elbows, unions, female adaptors, male adaptors and sealing fittings in galvanised steel, aluminium and stainless; BSP, NPT and metric thread options. Sealing fittings are filled with approved cable sealing compound to prevent the passage of gas and flame along the conduit; required at every entry into an Ex d or Ex e enclosure per IEC 60079-14.
Aluminium alloy and stainless steel cable cleats for single-core and trefoil three-core HV cables; rated to IEC 61914 for short-circuit withstand on Saudi substation cable runs. Short-circuit ratings of 25 kA, 40 kA and 63 kA peak current available; trefoil formation cleats maintain correct cable geometry on 11 kV and 33 kV circuits; IEC 61914 test reports supplied with each cleat type for engineering compliance.
GRP and stainless ATEX Zone 1/2 junction boxes with Ex d or Ex e certification; IP66/IP67; terminal block configurations 4–60 way; cable-entry options pre-drilled or with blind knockouts. GRP (glass-reinforced polyester) boxes resist Saudi Arabia coastal corrosion; stainless steel Ex d boxes for offshore and high-temperature locations; DIN-rail terminal blocks; earth bar; lid gasket inspected and replaced at every service.
Cable-gland sealing washers, reducer rings, lockrings, counter flanges and thread-seal PTFE tape for correct installation of cable-gland assemblies to IEC 60079-14 (electrical installations in hazardous areas). Stopping plugs in nylon and brass to close unused cable-gland entries; reducer rings to adapt large apertures to smaller cable-gland sizes; earthing lockrings to maintain electrical earth continuity between gland and enclosure.
All ATEX and IECEx certified products supplied with certificates, installation datasheets and cable-gland selection data. SASO and Saudi Aramco accepted IECEx certification. ISO 9001:2015 QMS (CR 4030570569). Inventory updated: September 2026.
| Product | ATEX Category | Material | Cable OD Range | IP Rating |
|---|---|---|---|---|
| Ex d Cable Gland — M20, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 5–14 mm cable OD | IP66 / IP68 |
| Ex d Cable Gland — M25, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 9–18 mm cable OD | IP66 / IP68 |
| Ex d Cable Gland — M32, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 14–24 mm cable OD | IP66 / IP68 |
| Ex d Cable Gland — M40, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 20–32 mm cable OD | IP66 / IP68 |
| Ex d Cable Gland — M50, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 28–42 mm cable OD | IP66 / IP68 |
| Ex d Cable Gland — M63–M75, Nickel-Plated Brass | II 2G Ex d IIC T6 / Zone 1 & 2 | Nickel-plated brass | 36–55 mm cable OD | IP66 / IP68 |
| Ex e Cable Gland — M20–M32, SS 316 | II 2G Ex e II T6 / Zone 1 & 2 | Stainless steel 316 | 5–24 mm cable OD | IP66 / IP68 |
| Ex e Cable Gland — M40–M50, SS 316 | II 2G Ex e II T6 / Zone 1 & 2 | Stainless steel 316 | 20–42 mm cable OD | IP66 / IP68 |
| Ex e Cable Gland — M63–M75, SS 316 | II 2G Ex e II T6 / Zone 1 & 2 | Stainless steel 316 | 36–55 mm cable OD | IP66 / IP68 |
| Armoured Cable Gland — SWA/DSTA, M20–M50, Brass | II 2G Ex d IIC / Zone 1 & 2 | Nickel-plated brass | 5–42 mm cable OD (armoured) | IP66 / IP68 |
| Armoured Cable Gland — SWA/DSTA, M63–M100, Brass | II 2G Ex d IIC / Zone 1 & 2 | Nickel-plated brass | 36–68 mm cable OD (armoured) | IP66 / IP68 |
| Armoured Cable Gland — STA, M50–M100, SS 316 | II 2G Ex d IIC / Zone 1 & 2 | Stainless steel 316 | 28–68 mm cable OD (STA armoured) | IP66 / IP68 |
| Unarmoured Cable Gland — M16–M50, Brass (Indoor/Outdoor) | Zone 2 / Non-hazardous area | Brass or nickel-plated brass | 3–40 mm cable OD | IP66 |
| Conduit Elbow — 1/2"–2", Galvanised Steel, Zone 1/2 | II 2G Ex e / Zone 1 & 2 | Hot-dip galvanised steel | 1/2" to 2" NPT / BSP conduit | IP54 (conduit system) |
| Conduit Elbow — 1/2"–2", Aluminium, Zone 1/2 | II 2G Ex e / Zone 1 & 2 | LM6 aluminium alloy | 1/2" to 2" NPT / BSP conduit | IP54 (conduit system) |
| Conduit Union — 1/2"–2", Steel/Aluminium | II 2G Ex e / Zone 1 & 2 | Galvanised steel or aluminium | 1/2" to 2" NPT / BSP conduit | IP54 (conduit system) |
| Conduit Sealing Fitting — 1/2"–2", Aluminium, Zone 1/2 | II 2G Ex d / Zone 1 & 2 | LM6 aluminium, sealing compound included | 1/2" to 2" NPT / BSP conduit | IP66 (sealed) |
| Conduit Male Adaptor — 1/2"–2" NPT to Metric | II 2G Ex e / Zone 1 & 2 | Galvanised steel or nickel-plated brass | NPT 1/2"–2" to metric M20–M63 | IP54 (conduit system) |
| Cable Cleat — Single-Core, Aluminium Alloy, IEC 61914 | Non-hazardous / safe area substations | Aluminium alloy (LM25) | Cable OD 20–120 mm | N/A (cable cleat) |
| Cable Cleat — Trefoil, Aluminium Alloy, 25 kA, 11 kV | IEC 61914, rated 25 kA peak | Aluminium alloy (LM25) | Trefoil — 3× cable OD 40–85 mm | N/A (cable cleat) |
| Cable Cleat — Trefoil, SS 316, 63 kA, 33 kV/132 kV | IEC 61914, rated 63 kA peak | Stainless steel 316 | Trefoil — 3× cable OD 60–140 mm | N/A (cable cleat) |
| GRP Junction Box — Ex d, 4–16 Way (Zone 1) | II 2G Ex d IIC T6 / Zone 1 & 2 | GRP (glass-reinforced polyester) | Multiple cable entries, pre-drilled or blank | IP66 / IP67 |
| GRP Junction Box — Ex e, 20–60 Way (Zone 1/2) | II 2G Ex e II T6 / Zone 1 & 2 | GRP (glass-reinforced polyester) | Multiple cable entries, pre-drilled or blank | IP66 / IP67 |
| Stainless Junction Box — Ex d, 4–24 Way (Zone 1) | II 2G Ex d IIC T6 / Zone 1 | Stainless steel 316L | Multiple cable entries, pre-drilled or blank | IP66 / IP67 |
| Stopping Plugs — M16–M75, Nylon & Brass | Zone 1 & 2 (IEC 60079-14 compliant) | Nylon PA66 or nickel-plated brass | M16, M20, M25, M32, M40, M50, M63, M75 | IP66 (when fitted) |
| Reducer Rings — Various metric sizes | Zone 1 & 2 (IEC 60079-14) | Nickel-plated brass | M20→M16, M25→M20, M32→M25, M40→M32 | IP66 (when fitted) |
| Earthing Lockrings — M20–M75 | Zone 1 & 2 (earth continuity) | Nickel-plated brass or stainless 316 | M20, M25, M32, M40, M50, M63, M75 | N/A (lockring accessory) |
| Brass Compression Glands — Non-ATEX, Dry Indoor Areas | Non-hazardous area, indoor/dry service | Brass, unplated | Cable OD 3–52 mm; M16–M63 | IP54 / IP65 |
Gulf Union Ozone holds the largest range of ATEX Ex d and Ex e cable glands in the GCC in stock at Jeddah; same-day dispatch for urgent Saudi Aramco and SABIC shutdown needs. Sizes M16–M100 in brass, stainless and aluminium available from stock without minimum order.
All hazardous-area cable glands and junction boxes carry IECEx certificates accepted by SASO and Saudi Aramco as equivalent to ATEX for classified-area installations. Full certificate documentation and installation datasheets supplied with every order for Saudi Aramco and SABIC project compliance files.
Products are selected to meet SAES-B-006 (Electrical Equipment), SAES-B-068 (Area Classification) and IEC 60079-14 (installation standard) requirements specified in Saudi Aramco engineering standards. Material certificates and ATEX/IECEx test reports supplied for each product type.
Gulf Union Ozone provides cable-gland selection based on cable OD, armouring type, area classification and IP requirement; sizing spreadsheets and installation datasheets supplied at no charge. Cable cleat spacing calculations based on IEC 61914 and system fault level also available on request.
Perforated, ladder and solid-bottom cable trays in galvanised steel, aluminium and fibreglass for Saudi Arabia industrial cable routing; NEMA VE 1 and IEC 61537 rated; stainless steel options for offshore and corrosive environments.
Instrument, control, power and data cables with ATEX and IECEx certified jacket compounds for Saudi Arabia hazardous-area installations; armoured and unarmoured options; SWA and DSTA armour; BASEC, SASO and IEC 60502 certified.
ATEX Zone 1 and Zone 2 GRP and stainless steel Ex d and Ex e electrical enclosures, motor control centre panels and distribution boards for Saudi Arabia oil & gas and petrochemical electrical installations; IECEx certified.
ATEX Ex d and Ex e LV and MV electric motors for Zone 1 and Zone 2 hazardous areas in Saudi Arabia; IE3 efficiency class; IEC 60034 rated; foot, flange and face-mount configurations for pump, compressor and fan drives at Saudi Aramco facilities.
Saudi Aramco SAES-B-006 requires Ex d IIC (flameproof) or Ex e II (increased safety) cable glands for Zone 1 areas. Ex d glands are preferred for power cables entering junction boxes and motor terminal boxes; Ex e glands are used for instrumentation cables entering Ex e enclosures. All glands must be ATEX or IECEx certified and installed per IEC 60079-14. Gulf Union Ozone supplies glands in nickel-plated brass (for standard Zone 1 service), 316 stainless (for offshore or coastal Saudi projects) and aluminium (for weight-critical applications).
Cable cleats are tested to IEC 61914 by applying the peak short-circuit current force to the cable and cleat assembly. The cleat rating is expressed as maximum current (kA peak, e.g. 25 kA, 40 kA, 63 kA) for a specified cable spacing and number of cycles. For Saudi 33 kV or 132 kV HV cable installations, the cleat spacing and peak fault current are calculated from the system fault level; Gulf Union Ozone selects aluminium alloy or stainless steel trefoil cleats to match. IEC 61914 test reports are provided with each cleat type.
Ex d (flameproof) glands are designed so that if an internal ignition occurs, the flame cannot propagate to the external hazardous atmosphere; they rely on long, close-tolerance flame paths in the gland body. They are mandatory for entries into Ex d enclosures (flameproof terminal boxes and junction boxes). Ex e (increased safety) glands prevent ignition by improved mechanical construction, keeping surface temperatures and sparking risk low; they are used with Ex e enclosures. Ex d glands can also be used in Ex e enclosures but not vice versa. Gulf Union Ozone's catalogue covers both types in M16–M100 metric threads.
To get a fast quotation, provide: product type (Ex d / Ex e / armoured / conduit fitting / cable cleat / junction box), thread size (metric / NPT / BSP), material (brass / stainless / aluminium), area classification (Zone 1 / Zone 2), cable OD or armour type, IP rating required, and delivery location in Saudi Arabia.
Recent Deliveries
CR 4030570569 | ISO 9001:2015 | Jeddah, Saudi Arabia — Saudi Aramco vendor compliance · SAEP-347 credentials
Technical content reviewed by Gulf Union Ozone's Engineering Team, Jeddah — 2026
Inventory updated: September 2026
Gulf Union Ozone Trading Co. supplies Cable Glands & Conduit Systems to industrial customers across Saudi Arabia with delivery from our Jeddah warehouse — all products ship with original certificates and compliance documentation for Aramco, SABIC, and government projects.
Cable Glands & Conduit Systems from Gulf Union Ozone serves Saudi Aramco operations, SABIC, SADARA, SEC utilities, NEOM mega-projects, and major industrial facilities across the Kingdom — our inventory covers the most common specifications and ratings.
Gulf Union Ozone stocks a comprehensive range of Cable Glands & Conduit Systems — contact us for immediate availability confirmation and a competitive quotation with full compliance documentation and MTC traceability.
For urgent Cable Glands & Conduit Systems procurement in Saudi Arabia, WhatsApp +966 55 098 8062 — our team confirms stock availability within the hour and provides competitive quotations with full compliance documentation for all industrial sectors.