Gulf Union Ozone supplies variable frequency drives (VFDs), AC inverters, soft starters, motor control centres (MCCs), and regenerative drives for industrial motor speed control, energy saving, and process optimisation across Saudi Arabia. Our inventory covers general-purpose and heavy-duty low-voltage VFDs (0.37kW–630kW), soft starters (7A–1200A), intelligent MCCs, and regenerative active front-end drives — all to IEC 61800 series standards with IGBT power stage technology, EMC Class C2 filters, and MODBUS RTU built-in as standard.
Enclosure protection classes IP20 (panel mount), IP54, and IP55 (outdoor) available to suit Saudi Arabia's dusty and high-ambient-temperature environments. SIL2 safety function (Safe Torque Off) fitted as standard on all current-range models. ISO 9001:2015 certified (CR 4030570569). Same-day dispatch from our Jeddah warehouse.

Gulf Union Ozone carries six drive and motor control product families to IEC 61800 and IEC 60947-4-2 standards — with full certification documentation and fieldbus configuration support for Saudi Arabia industrial projects.
Scalar (V/f) and vector control VFDs for general-purpose pump, fan, conveyor, and compressor speed control in Saudi Arabia industrial facilities. Three-phase 380–480V input, 50/60Hz, IGBT power stage with carrier frequency 2–16kHz, overload capacity 110% for 60 seconds (normal duty) or 150% for 60 seconds (heavy duty). Built-in EMC filter Class C2 (IEC 61800-3 Second Environment), built-in DC choke on 11kW and above, built-in brake transistor on units to 22kW. MODBUS RTU RS-485 as standard. Keypad with LCD display, multi-language menu. IP20 chassis for panel mounting; IP55 wall-mount version available. Integrated PID controller for pressure and flow regulation on pump and HVAC applications. Operating temperature 0°C to 50°C ambient.
High-overload (150% / 60s, 180% / 3s) VFDs for demanding industrial loads — crusher drives, conveyor starting, centrifuge drives, and reciprocating compressors with high inertia in Saudi Arabia process plants. Sensorless flux vector (SFV) and closed-loop field-oriented control (FOC) with encoder feedback options for precise speed and torque regulation. IP54 or IP55 enclosure rated to 50°C ambient (60°C with derating). Safe Torque Off (STO) function to SIL2 / PL-d (IEC 62061 / ISO 13849-1) as standard — enabling integration with safety relay circuits without additional hardware. PROFIBUS DP, PROFINET, EtherNet/IP, and DeviceNet fieldbus option cards. Modular design with plug-in option cards for I/O expansion, encoder, and brake chopper. Suitable for pump VFD retrofits on existing NEMA or IEC motor installations.
Thyristor (SCR) soft starters to IEC 60947-4-2 for controlled motor start-up and soft stop — reducing mechanical shock on pump impellers, gearboxes, and conveyor belts, and eliminating water hammer in Saudi Arabia piping systems. Voltage ramp and current limit starting modes; adjustable ramp time 1–30 seconds. Built-in bypass contactor on units 75A and above (eliminates SCR heating during run). Built-in motor protection: overload, phase loss, phase imbalance, thermistor input. IP20 chassis or IP55 wall-mount enclosure. Current range 7A (1.5kW) to 1200A (630kW). Three-phase 380–480V, 50/60Hz. MODBUS RTU RS-485 standard on all current ratings 30A and above. Suitable for centrifugal pumps, belt conveyors, compressors, and fan drives. Full overload protection curves and application guidelines available on request.
Intelligent motor control centres (MCCs) with combination starter sections — direct-on-line (DOL), star-delta (Y/Δ), and VFD or soft-starter combinations — in fully type-tested assemblies to IEC 61439-2 (Form 3b or 4 internal separation). MCC construction: floor-standing double-front or single-front, 200mm or 400mm section width, busbar rating 630A–3200A, IP31 standard with IP54 option. Intelligent motor controllers (IMCs) with MODBUS or PROFIBUS integration for remote monitoring of motor current, power, and fault status from DCS in Saudi Arabia plant control rooms. Outgoing ways fitted with motor protection circuit breakers (MPCBs) and contactors from major brands. Withdrawable plug-in motor starter units for live maintenance. Factory-built, type-tested, delivered ready to wire.
Regenerative (four-quadrant) VFDs with active front-end (AFE) rectifier for returning braking energy to the supply network — eliminating braking resistors and reducing energy consumption on crane hoist drives, centrifuge decelerations, downhill conveyor systems, and test bench drives in Saudi Arabia. AFE units maintain near-unity power factor (PF 0.99) and significantly reduce harmonic current distortion (THDi typically below 5%) compared with standard diode-bridge VFDs — critical for facilities with strict power quality requirements from SEC. Voltage: 380–480V / 3ph / 50Hz. Power range 11kW–800kW. 12-pulse or 18-pulse input transformer option for legacy installations with harmonic concerns. MODBUS RTU standard; PROFIBUS and EtherNet/IP optional. IP20 or IP54 enclosure.
EMC line filters (IEC 61800-3 Class C1 / C2) for VFDs installed close to sensitive instrumentation and communication equipment in Saudi Arabia process plants. Line reactors (AC input choke) 3–5% impedance for harmonic reduction, protection against supply transients, and extended VFD IGBT life — essential where supply impedance is low (near transformer secondary). dV/dt output filters and sine-wave filters for long cable runs from VFD to motor (above 50m) — prevent insulation stress in inverter-duty motors. Motorised bypass contactors with manual changeover for critical pump and fan drives requiring uninterrupted operation during VFD maintenance. Braking resistors (dynamic braking) IP20 and IP55 for high-inertia loads. All accessories matched and rated for VFD power range 0.37kW–630kW.
All drives and soft starters supplied with CE Declaration of Conformity, EMC test reports, and STO SIL2 certificates where applicable. ISO 9001:2015 QMS (CR 4030570569). Stocked in Jeddah.
| Product | Standard / Spec | Technology / Enclosure | Power / Current Range | Application |
|---|---|---|---|---|
| General Purpose VFD — Scalar V/f Control, IP20 | IEC 61800-2 / EMC Class C2 | IGBT, IP20, built-in EMC filter, MODBUS RTU | 0.37kW–7.5kW / 1.0A–17A | Small pumps, fans, conveyors, HVAC air handling units |
| General Purpose VFD — V/f Control, IP20, Mid-Range | IEC 61800-2 / EMC Class C2 / STO SIL2 | IGBT, IP20, DC choke, brake transistor built-in | 11kW–22kW / 24A–46A | Pump and fan speed control, conveyor variable speed |
| General Purpose VFD — V/f Control, IP20, Large Frame | IEC 61800-2 / EMC Class C2 / STO SIL2 | IGBT, IP20, DC choke, EMC filter, MODBUS RTU | 30kW–110kW / 62A–210A | Medium centrifugal pumps, large HVAC fans, water supply stations |
| General Purpose VFD — V/f Control, IP20, High Power | IEC 61800-2 / EMC Class C2 / STO SIL2 | IGBT, IP20, DC choke, EMC filter, forced air cooling | 132kW–315kW / 260A–600A | Large pump stations, cooling tower drives, process compressors |
| VFD — IP55 Wall-Mount, 50°C Ambient (Outdoor Duty) | IEC 61800-2 / IEC 60529 IP55 / EMC Class C2 | IGBT, IP55 steel enclosure, fan-cooled, MODBUS RTU | 0.37kW–90kW / 1.0A–175A | Outdoor pump stations, desalination pre-treatment, irrigation pumps |
| Heavy Duty VFD — Sensorless Flux Vector, IP20, Normal/Heavy Duty | IEC 61800-2 / EMC C2 / STO SIL2 / 150% / 60s | IGBT, SFV control, MODBUS RTU, ProfiBus DP optional | 11kW–160kW / 24A–310A | Crusher, heavy conveyor, centrifuge, high-inertia compressor |
| Heavy Duty VFD — Closed-Loop FOC, Encoder Feedback, IP20 | IEC 61800-2 / STO SIL2 / FOC + encoder input | IGBT, closed-loop vector, 24V DC encoder card, IP20 | 5.5kW–315kW / 13A–600A | Precision speed/torque control — winding machines, hoists, test benches |
| Heavy Duty VFD — IP54, 50°C Ambient, PROFIBUS DP | IEC 61800-2 / IEC 60529 IP54 / EMC Class C2 | IGBT, IP54, PROFIBUS DP card fitted, STO SIL2 | 22kW–630kW / 46A–1200A | Process drives integrated into Siemens S7 / PCS 7 DCS systems |
| Soft Starter — 7A–50A, IP20, MODBUS RTU | IEC 60947-4-2 / Class 10 / 380–480V | Thyristor (SCR), IP20 chassis, MODBUS RTU 30A+ | 7A–50A / 1.5kW–22kW at 400V | Small pump and fan DOL replacement, belt conveyor soft start |
| Soft Starter — 60A–180A, Bypass Contactor Built-In, IP20 | IEC 60947-4-2 / Class 10 / Bypass contactor | Thyristor SCR + internal bypass contactor, MODBUS RTU | 60A–180A / 30kW–90kW at 400V | Centrifugal pump water hammer elimination, compressor controlled start |
| Soft Starter — 200A–500A, Bypass, IP20, Heavy Duty | IEC 60947-4-2 / 380–480V / Class 20 | Thyristor SCR + bypass, full motor protection, MODBUS RTU | 200A–500A / 110kW–250kW at 400V | Large pump stations, desalination high-lift pumps, cooling tower fans |
| Soft Starter — 600A–1200A, IP20, Very Large Motors | IEC 60947-4-2 / 380–690V / Class 20 | Thyristor SCR, forced cooling, bypass, PROFIBUS DP | 600A–1200A / 315kW–630kW at 400V | Large refinery pumps, desalination seawater intake pumps, blast fans |
| Soft Starter — IP55 Wall-Mount (Outdoor Duty), 30A–200A | IEC 60947-4-2 / IEC 60529 IP55 | Thyristor SCR, IP55 wall-mount, MODBUS RTU | 30A–200A / 15kW–110kW at 400V | Outdoor pump stations and agricultural irrigation with no control room |
| Motor Control Centre (MCC) — DOL Starters, IEC 61439-2 Form 3b | IEC 61439-2 Form 3b / IEC 60947-4-1 | Floor-standing, busbar 630A–1600A, IP31/IP54 | Motor feeders 0.37kW–200kW per section | Pump station motor control, water treatment plant MCC |
| Motor Control Centre (MCC) — VFD + DOL Combination, Form 4 | IEC 61439-2 Form 4 / IEC 61800-2 | Floor-standing, VFD drawers + DOL starters, IP31 | Mixed VFD 0.37kW–315kW + DOL to 200kW per MCC | Desalination plant motor control, refinery utility pump station |
| Intelligent MCC — Fieldbus-Enabled with IMC Modules, PROFIBUS | IEC 61439-2 / IEC 61800-2 / PROFIBUS DP V1 | IMC modules per motor feeder, DCS-ready, IP31/IP54 | Motor feeders to 250kW per section / PROFIBUS DP network | Saudi Aramco, SABIC, and SEC plant DCS motor monitoring |
| Regenerative Drive — 4-Quadrant AFE, IP20 | IEC 61800-2 / AFE IGBT rectifier / THDi <5% | IGBT active front-end, unity power factor, IP20 | 11kW–400kW | Crane hoists, centrifuges, downhill conveyors — braking energy recovery |
| EMC Line Filter — IEC Class C1, Panel Mount | IEC 61800-3 Class C1 (First Environment) | Single-phase or three-phase, IP20 chassis mount | 1A–500A / 0.37kW–250kW at 400V | VFD EMC upgrade near sensitive instrumentation or commercial buildings |
| AC Line Reactor — 3% Impedance, Three-Phase | IEC 61800-3 / UL 508A rated choke | Three-phase iron-core reactor, IP00 chassis | 6A–600A / 2.2kW–315kW at 400V | Harmonic reduction and supply transient protection at VFD input |
| AC Output Reactor (dV/dt Filter) — Long Cable Duty | IEC 61800-3 / dV/dt <500V/µs at 100m cable | Three-phase output choke, IP00 chassis, 400V rated | 6A–300A / 2.2kW–160kW | VFD to motor cable runs above 50m — protects motor winding insulation |
| Sine-Wave Output Filter — Long Cable, Motor Friendly | IEC 61800-3 / THD voltage <3% at output | LC filter, IP20 chassis or IP54 enclosure | 6A–200A / 2.2kW–110kW | Old motors (non-inverter-duty) driven by VFD — long cable or old winding |
| Braking Resistor — IP20, Stainless Wire Wound | IEC 61800-2 matched to VFD brake transistor | Stainless wire wound, IP20 chassis or IP54 mesh guard | Matched 0.37kW–160kW VFD braking duty | Dynamic braking for hoists, centrifuges, test rigs with high inertia |
| Motorised Bypass Contactor — VFD Bypass Panel, IP31 | IEC 60947-4-1 / IEC 61439-2 | Steel panel, mechanical interlock, MPCB, contactor | Suits VFD 0.37kW–250kW motor circuits | Critical pump and fan drives requiring DOL run during VFD maintenance |
| PROFIBUS DP Option Card for VFD | PROFIBUS DP V1 / IEC 61158 | Plug-in option card, 9-pin DB connector, 12Mbit/s | All VFD models 0.37kW–630kW (option slot required) | Fieldbus integration with Siemens S7 PLC / PCS 7 DCS |
| EtherNet/IP Option Card for VFD | EtherNet/IP / ODVA CIP / IEC 61158 | Plug-in option card, RJ45 Ethernet port, 100Mbit/s | All VFD models with option slot, 0.37kW–630kW | Allen-Bradley / Rockwell PLC integration, TCP/IP plant network |
| Remote Keypad & Extension Cable — VFD Panel Mounting Kit | OEM-matched to VFD model, IP54 panel-mount bezel | LCD keypad, RJ45 extension cable 1m–5m, IP54 gasket | Suits all VFD models with remote keypad port | MCC door-mount remote operator panel for VFD inside closed cubicle |
| Safety Relay — STO (Safe Torque Off), SIL2 / PLd | IEC 62061 SIL2 / ISO 13849-1 PLd | DIN rail mount, 24V DC, 35mm wide | 2-channel safety relay, response time <20ms | Emergency stop safety circuit for VFD and servo drive motor control panels |
Core general-purpose VFDs (0.37kW–90kW) and soft starters (7A–200A) are stocked in Jeddah for immediate dispatch — critical for minimising pump and fan downtime at Saudi Arabia water, oil and gas, and industrial facilities.
CE Declaration of Conformity, EMC test certificates (IEC 61800-3), STO SIL2 certificates (IEC 62061), and SASO import data supplied with every drive. Fieldbus wiring diagrams and parameter lists available for major DCS platforms.
Gulf Union Ozone is ISO 9001:2015 certified (CR 4030570569), Jeddah, Saudi Arabia — all drives inspected on receipt and traceability records maintained for every batch dispatched.
Delivery to all 18 Saudi regions — Jubail, Yanbu, Dammam, Riyadh, Jizan, Tabuk, and beyond. Emergency VFD replacement dispatched same-day from Jeddah for critical plant breakdowns.
IEC IE3 induction motors, Ex-d explosion-proof motors, and TEFC enclosed motors for pump and fan drives in Saudi Arabia.
GRP, stainless steel, and ATEX junction boxes and distribution boards for VFD and motor control panels in Saudi Arabia plants.
HDG perforated cable trays, ladder trays, conduit, and trunking for VFD power and control cabling in Saudi Arabia projects.
Maintenance supplies, cable glands, terminal blocks, and consumables to support electrical panel installation and maintenance in Saudi Arabia.
Gulf Union Ozone supplies variable frequency drives in IP20 (indoor panel mounting), IP54 (dusty indoor or sheltered outdoor), and IP55 (outdoor duty) protection ratings to IEC 60529 — essential for Saudi Arabia's dusty desert environments and coastal humidity. For installation in hazardous Zone 2 areas, we supply ATEX-rated IP65 VFD enclosures with purge-and-pressurisation (Ex-p) systems to IEC 60079-13. Wall-mount, floor-standing, and panel-built VFD assemblies are available. All units are rated to 50°C ambient as standard, with derating curves for higher temperatures available in the datasheet. Contact us on WhatsApp 966550988062 for enclosure selection guidance.
Yes. Gulf Union Ozone stocks VFDs with built-in MODBUS RTU (RS-485) as standard on most units — the most common fieldbus protocol used in Saudi Arabia oil and gas, water treatment, and desalination plant DCS and SCADA systems. PROFIBUS DP, DeviceNet, EtherNet/IP, and PROFINET communication cards are available as plug-in option modules for all major VFD brands we supply. Fieldbus-enabled drives support remote start/stop, speed reference, fault monitoring, and energy data logging without additional signal converters. We can provide pre-configured drives with your specific register map on request. Full wiring diagrams and fieldbus configuration documentation included.
Yes. Soft starters are the primary solution for controlling pump start-up ramp rates in water supply, sewage pumping, and desalination projects across Saudi Arabia to eliminate water hammer and reduce mechanical stress on pipework and pump impellers. Gulf Union Ozone stocks electronic soft starters in 7A–1200A current ratings (IEC 60947-4-2) with adjustable current ramp, voltage ramp, and pump-deceleration (soft stop) control. Built-in bypass contactor for full-voltage run reduces thermal load on power semiconductors. Thyristor (SCR) technology, IP20 chassis or IP55 standalone enclosure. Suitable for centrifugal pumps up to 630kW. Documentation includes CE declaration of conformity and SASO import compliance data.
To get a fast quotation, provide: motor power (kW), supply voltage and frequency, enclosure protection class (IP20/IP54/IP55), control mode (scalar/vector), fieldbus requirement (MODBUS/PROFIBUS/EtherNet/IP), and delivery location in Saudi Arabia.
Recent Deliveries
CR 4030570569 | ISO 9001:2015 | Jeddah, Saudi Arabia — Saudi Aramco vendor compliance · SAEP-347 credentials
Technical content reviewed by Gulf Union Ozone’s Engineering Team, Jeddah — 2026
Inventory updated: August 2026
Gulf Union Ozone Trading Co. supplies Variable Frequency Drives to industrial customers across Saudi Arabia with delivery from our Jeddah warehouse — all products ship with original certificates and compliance documentation for Aramco, SABIC, and government projects.
Variable Frequency Drives from Gulf Union Ozone serves Saudi Aramco operations, SABIC, SADARA, SEC utilities, NEOM mega-projects, and major industrial facilities across the Kingdom — our inventory covers the most common specifications and ratings.
Gulf Union Ozone stocks a comprehensive range of Variable Frequency Drives — contact us for immediate availability confirmation and a competitive quotation with full compliance documentation and MTC traceability.
For urgent Variable Frequency Drives procurement in Saudi Arabia, WhatsApp +966 55 098 8062 — our team confirms stock availability within the hour and provides competitive quotations with full compliance documentation for all industrial sectors.