Gulf Union Ozone stocks a comprehensive range of industrial electrical enclosures and junction boxes for power distribution, instrument termination, and control panel housing across Saudi Arabia's oil and gas, petrochemical, water, and infrastructure projects. Our inventory covers GRP (glass-reinforced polyester) fibreglass enclosures, stainless steel 316L junction boxes, powder-coated steel distribution boards, polycarbonate instrument boxes, and ATEX IECEx certified explosion-proof enclosures for Zone 1 and Zone 2 hazardous areas.
All enclosures are rated to IEC 60529 IP65, IP66, or IP67 as specified. NEMA 4X equivalent GRP and SS boxes available. ATEX certified to IEC 60079-1 (Ex-d) and IEC 60079-7 (Ex-e). RAL 7035 powder-coat finish as standard on steel enclosures. ISO 9001:2015 certified (CR 4030570569). Same-day dispatch from our Jeddah warehouse.

Gulf Union Ozone carries six electrical enclosure families to IEC 60529, NEMA 4X, ATEX, and IECEx standards — with complete certification documentation for every enclosure supplied to Saudi Arabia industrial projects.
Glass-reinforced polyester (GRP) fibreglass electrical enclosures to IEC 60529 IP65 and IP66 — the primary choice for outdoor, coastal, and corrosive industrial environments in Saudi Arabia where carbon steel would require frequent repainting and corrodes rapidly in salt-laden marine air. GRP enclosures are non-corroding, non-magnetic, UV-stable, lightweight (up to 60% lighter than equivalent steel), and self-extinguishing (UL 94 V-0 flame class). Standard range: 80×80×55mm (small instrument box) through 600×500×200mm (large marshalling box). Colour: RAL 7032 pebble-grey standard. Lid fixing: 4× stainless steel 316L quarter-turn or screw fixings. Gland plate: removable, drilled on request. Internal DIN rail and terminal block mounting available. Used extensively in Saudi Arabia oil and gas instrument loops, coastal pump stations, water treatment junction boxes, and desalination facility field wiring. Transparent lid polycarbonate versions also stocked.
AISI 316L stainless steel junction boxes and instrument enclosures to IEC 60529 IP65 and IP66 for chemical process plants, desalination facilities, food and pharmaceutical production, and marine environments in Saudi Arabia. 316L (low-carbon molybdenum-alloyed SS) provides superior pitting and crevice corrosion resistance over standard 304 SS — essential in chloride-rich coastal environments around Jeddah, Jubail, and Yanbu. Standard range: 100×100×75mm through 800×600×300mm. Lid: full-perimeter EPDM gasket, countersunk M5 or M6 SS screws. Internal: M5 earth stud, 35mm DIN rail pre-fitted on larger sizes. Gland plate: 2mm SS, pre-drilled or blank. Wall-mounting: 4× welded M6 stud feet on rear panel. Used for instrument junction boxes, thermocouple head boxes, cable termination boxes, and small local control panels. Brushed (2B) or mirror-polished (BA) finish on request for food-grade applications.
Powder-coated mild steel electrical distribution boards, wall-mount and floor-standing control panel enclosures, and multi-door cubicles for motor control, power distribution, and instrument panel applications in Saudi Arabia. Finish: RAL 7035 light grey powder coat (60–80µm), textured inside and outside, UV-resistant. IP55 wall-mount enclosures: 300×200×150mm through 1200×1000×300mm — used for local motor control panels, lighting distribution boards, and small instrument panels at outdoor pump stations and plant areas. Floor-standing multi-door cubicles (IP31/IP54): 600mm–1200mm wide × 600mm deep × 2000mm high — for MCCs, main distribution boards, and power control panels in substations and electrical rooms. Mounting plate: anti-corrosion zinc-phosphate pre-treated, RAL 7035 powder coat. Cable entry: bottom and top gland plates, removable. Supplied with internal 35mm DIN rail mounting strips, 63A–400A busbar pre-fitted on distribution board versions.
ATEX and IECEx certified explosion-proof electrical enclosures for Zone 1 (Ex-d flameproof) and Zone 2 (Ex-e increased safety) hazardous areas in Saudi Arabia oil and gas, refinery, and chemical plant environments. Ex-d (flameproof) enclosures: cast aluminium or GRP body, IP65 or IP66, Group IIA and IIB (standard) and IIC (hydrogen service) — used for junction boxes, marshalling boxes, pushbutton stations, and instrument housings in Zone 1 where electrical sparks could ignite flammable atmospheres. Ex-e (increased safety) enclosures: GRP and stainless steel, IP65, Zone 2 — for passive cable terminations, lighting distribution, and signal conditioning in Zone 2 designated areas. T4 (135°C) and T5 (100°C) temperature classes standard. All ATEX/IECEx units supplied with Ex certificate (IECEx certificate number), marking plate (e.g. Ex-d IIB T4 Gb), ingress protection test report, and installation instructions. Stainless 316L Ex-e boxes for H2S service also available.
Transparent-lid polycarbonate (PC) and opaque ABS plastic instrument enclosures to IEC 60529 IP65 and IP67 for field-mounted instruments, signal converters, transmitters, and small control devices in Saudi Arabia plant areas. Polycarbonate enclosures: UV-stabilised, IK08 impact-resistant, transparent lid for visual inspection of terminal status without opening. Standard sizes: 83×58×34mm (single-instrument) through 300×220×120mm (multi-instrument). Rapid-release quarter-turn stainless screws; full EPDM perimeter gasket; IP67 (submersible to 1m). ABS enclosures: solid opaque lid, RAL 7032, quarter-turn fixings, IP65. Both materials rated for operating temperature -40°C to +80°C — suitable for Saudi Arabia's outdoor summer temperatures. Used for 4–20mA loop isolators, temperature transmitters, pressure transmitters, and PLC I/O modules on outdoor field junction boxes. Custom cut-outs for display windows and cable glands on request.
Multi-compartment electrical enclosures with internal dividing partitions for segregating ELV, LV, and hazardous-voltage cable terminations in a single box — common in Saudi Arabia oil and gas instrument marshalling panels, telecom IDF/MDF enclosures, and PLC panel assemblies. GRP dual-compartment boxes with internal ELV and LV separation: 400×300×150mm through 800×600×200mm. Stainless steel multi-terminal boxes with segregated chambers and individual earth bars for instrument earthing: 600×400×150mm through 1200×600×200mm. Lockable hinged-door enclosures in powder-coated steel for secure distribution board applications in public-access areas (IP65, stainless padlock hasp). Underground (pit-mounted) IP68 enclosures (submersible to 3m) for buried cable junction pits and below-grade instrument installations in Saudi Arabia infrastructure projects. All enclosures can be fitted with cable glands, terminal blocks, DIN rail, earthing bars, and labels per project bill of materials.
All enclosures supplied with IEC 60529 IP rating certificates, and ATEX/IECEx certificates where applicable. ISO 9001:2015 QMS (CR 4030570569). Stocked in Jeddah.
| Product | Standard / Cert | Material / Finish | Size Range | Application |
|---|---|---|---|---|
| GRP Junction Box — IP65, Small Series | IEC 60529 IP65 / UL 94 V-0 | GRP polyester, RAL 7032, SS 316L screws | 80×80×55mm / 100×100×70mm / 150×110×70mm | Instrument field JB, instrument loop termination, loop check |
| GRP Junction Box — IP65, Medium Series | IEC 60529 IP65 / UL 94 V-0 | GRP polyester, RAL 7032, EPDM gasket, earth stud | 200×150×80mm / 300×200×100mm / 400×300×150mm | Field marshalling box, motor junction box, control station housing |
| GRP Junction Box — IP66, Large Marshalling Series | IEC 60529 IP66 / UL 94 V-0 | GRP polyester, RAL 7032, stainless hinged lid, EPDM gasket | 500×400×200mm / 600×500×200mm / 800×600×250mm | Instrument marshalling, multi-cable JB, field PLC I/O housing |
| GRP Enclosure — Transparent Polycarbonate Lid, IP65 | IEC 60529 IP65 / UL 94 V-0 | GRP body, clear polycarbonate lid, SS quarter-turn | 150×110×70mm / 200×150×80mm / 300×200×100mm | Visual inspection of terminal status without opening — instrument JBs |
| Stainless Steel Junction Box — 316L, IP65, Small Series | IEC 60529 IP65 / AISI 316L material | AISI 316L SS, 1.5mm, brushed 2B finish, EPDM gasket | 100×100×75mm / 160×130×90mm / 200×200×80mm | Food, pharma, marine, desalination — high-hygiene or corrosive duty |
| Stainless Steel Junction Box — 316L, IP66, Medium Series | IEC 60529 IP66 / AISI 316L material | AISI 316L SS, 2mm, hinged lid with quarter-turn, EPDM | 300×300×150mm / 400×300×200mm / 500×400×200mm | Chemical process, coastal outdoor, wash-down area termination boxes |
| Stainless Steel Junction Box — 316L, IP66, Large Marshalling | IEC 60529 IP66 / AISI 316L material | AISI 316L SS, 2mm, DIN rail pre-fitted, EPDM, earth stud M8 | 600×500×250mm / 800×600×300mm / 1000×800×300mm | Process plant marshalling enclosures — corrosive coastal locations |
| Steel Distribution Board — IP55, Wall-Mount, RAL 7035 | IEC 60529 IP55 / IEC 61439-3 | Mild steel, RAL 7035 powder coat 60µm, DIN rail inside | 300×200×150mm to 800×600×250mm | Local power distribution, lighting DB, small control panels |
| Steel Enclosure — IP65, Wall-Mount, Outdoor Duty | IEC 60529 IP65 / IEC 61439 | Mild steel, RAL 7035 powder coat, EPDM gasket, lockable | 400×300×200mm to 1200×1000×300mm | Outdoor motor control panels, pump station control boxes |
| Floor-Standing Cubicle — IP31, Steel, 2000mm High | IEC 60439-1 / IEC 61439-2 / IP31 | Mild steel, RAL 7035, cable entry top/bottom gland plates | 600–1200mm wide × 600mm deep × 2000mm high | MCC, main distribution board, LV switchgear enclosure |
| Floor-Standing Cubicle — IP54, Steel, Dustproof | IEC 60439-1 / IP54 | Mild steel, RAL 7035 powder coat, IP54 gasket door | 600–1200mm wide × 600mm deep × 2000mm high | Dusty plant rooms, outdoor substations, VFD drive panels |
| ATEX Ex-d Junction Box — GRP, Zone 1, Group IIB, T4 | IEC 60079-1 / ATEX IECEx / Ex-d IIB T4 Gb / IP66 | GRP flameproof body, stainless hardware, IP66 | 150×110×70mm / 300×200×100mm / 400×300×150mm | Zone 1 field instrument JB — oil and gas, refinery, chemical plant |
| ATEX Ex-d Junction Box — Cast Aluminium, Zone 1, Group IIC, T4 | IEC 60079-1 / ATEX IECEx / Ex-d IIC T4 Gb / IP66 | Cast aluminium, chromate passivated, IP66 | 150×110×70mm to 600×500×200mm | Zone 1 IIC — hydrogen, acetylene gas service, maximum hazard areas |
| ATEX Ex-e Enclosure — GRP, Zone 2, Increased Safety, IP65 | IEC 60079-7 / ATEX IECEx / Ex-e IIC T4 Gc / IP65 | GRP, RAL 7032, EPDM gasket, SS hardware | 200×150×80mm to 800×600×250mm | Zone 2 — passive terminal boxes, cable marshalling, lighting DB |
| ATEX Ex-e Enclosure — 316L Stainless Steel, Zone 2, IP66 | IEC 60079-7 / ATEX IECEx / Ex-e IIC T4 / IP66 | AISI 316L SS, 2mm, EPDM, SS hardware | 300×200×100mm to 600×500×200mm | Zone 2 in H2S service, coastal corrosive hazardous areas |
| Polycarbonate Enclosure — Transparent Lid, IP67 | IEC 60529 IP67 / UL 94 V-0 | Polycarbonate UV-stabilised, transparent or opaque lid | 83×58×34mm to 300×220×120mm | Field transmitter housing, signal isolator, temperature converter |
| ABS Plastic Enclosure — IP65, Grey, Solid Lid | IEC 60529 IP65 / UL 94 V-0 | ABS, RAL 7032 grey, neoprene gasket, SS screws | 100×100×50mm to 400×300×130mm | Light-duty indoor instrument housing, relay boxes, small panels |
| Dual-Compartment GRP Box — IP65, ELV/LV Segregated | IEC 60529 IP65 / IEC 60664-1 segregation | GRP, internal GRP divider, 2× separate chambers | 400×300×150mm to 800×600×200mm | Instrument marshalling with separate ELV/LV voltage zones |
| Underground Pit Box — IP68, GRP or Polycarbonate, 3m Submersible | IEC 60529 IP68 (3m / 30min) / IEC 61386 | GRP or polycarbonate, SS fasteners, foam-seal lid | 200×200×100mm to 600×400×200mm | Buried cable junction pits, below-grade instrument nodes |
| Lockable Hinged-Door Steel Enclosure — IP65, with Padlock Hasp | IEC 60529 IP65 / IEC 62262 IK09 | Steel, RAL 7035, EPDM, SS padlock hasp, IK09 rated | 400×300×200mm to 1200×1000×300mm | Secure distribution boards in public or semi-public access areas |
| Pushbutton Station — GRP, IP65, 1–4 Operator Holes | IEC 60529 IP65 / IEC 60947-5-1 | GRP, 22mm operator cutouts, stainless fixings, EPDM gasket | 1-hole to 4-hole pushbutton station enclosure | Field start/stop pushbutton and E-stop station for motors |
| ATEX Pushbutton Station — Ex-d, Zone 1, GRP, IP66 | IEC 60079-1 / ATEX IECEx / Ex-d IIB T4 / IP66 | GRP flameproof, 22mm operators, Zone 1 rated | 1-hole to 4-hole operators / Ex-certified | Zone 1 motor start/stop and E-stop pushbutton stations |
| Cable Gland — Nickel-Plated Brass, NPT / Metric, IP68 | IEC 60529 IP68 / BS 6121 cable gland | Nickel-plated brass, EPDM seal, neoprene clamping ring | M16–M63 metric / 1/2"–2" NPT / cable OD 4–52mm | Cable entry sealing for all enclosure types — armoured and unarmoured |
| ATEX Cable Gland — Ex-d, Nickel-Plated Brass, Zone 1 | IEC 60079-1 / ATEX IECEx Ex-d / IP66 | Nickel-plated brass, flame barrier seal, SS locknut | M20–M63 metric / armoured and unarmoured cable | Zone 1 hazardous area cable entry into Ex-d enclosures |
| DIN Rail — Top Hat TS 35 × 7.5mm, Galvanised or SS | DIN EN 60715 TS 35 × 7.5mm | Galvanised steel or AISI 304 SS, punched or solid, 1m lengths | Width 35mm × Height 7.5mm × Length 1m (cut to length) | Terminal block, relay, and MCB mounting inside all enclosure types |
| Terminal Block — Screw Clamp, DIN Rail, 2.5mm²–16mm² | IEC 60947-7-1 / UL 508 listed | PA66 body, copper alloy contact, TS35 DIN rail snap-fit | 2.5mm² (24A) / 4mm² (32A) / 6mm² (41A) / 10mm² / 16mm² | Signal and power wiring termination inside all enclosure types |
| Earthing Bar — Copper, DIN Rail Mount, 12-Way | IEC 60947-7-2 / BS 7671 protective conductor | Electrolytic copper, tin-plated, TS35 DIN rail mount | 6-way / 12-way / 20-way; suits 1.5mm²–16mm² conductors | Protective earth and instrument earth bus inside enclosures |
Core GRP junction boxes (IP65, 150×110mm to 400×300mm), stainless steel JBs (IP66, 316L), and steel wall-mount enclosures (IP55/IP65) stocked in Jeddah for immediate dispatch to Saudi Arabia construction and maintenance projects.
IEC 60529 IP-rating certificates, ATEX/IECEx Ex certificates (IECEx certificate number and marking plate details), and 316L stainless material certificates supplied with every enclosure order. SASO import compliance data on request.
Gulf Union Ozone is ISO 9001:2015 certified (CR 4030570569), Jeddah — incoming inspection on all enclosures with IP gasket integrity and finish quality checks. Traceability maintained per batch for project documentation.
Delivery to all 18 Saudi regions — Riyadh, Dammam, Jubail, Yanbu, Tabuk, Abha, Jizan, and beyond. Large project quantities and custom-cut gland plates dispatched from Jeddah warehouse.
HDG perforated trays, ladder trays, GRP trays, conduit, and cable ties for routing power and instrument cables to enclosures in Saudi Arabia.
IEC IE3 induction motors and ATEX Ex-d explosion-proof motors paired with Ex-rated junction boxes for Zone 1/2 hazardous area motor installations.
VFDs, soft starters, and MCCs supplied with IP54/IP55 steel and GRP enclosures for outdoor motor control in Saudi Arabia industrial plants.
Cable glands, DIN rail, terminal blocks, earthing bars, and general electrical consumables for panel wiring and enclosure assembly in Saudi Arabia.
Gulf Union Ozone supplies electrical enclosures and junction boxes in IP65, IP66, and IP67 protection ratings to IEC 60529 — the standard grades required for outdoor and wet-process industrial installations in Saudi Arabia. IP65 (dust-tight, protected against low-pressure water jets) is the minimum for outdoor junction boxes and instrument enclosures on Saudi Arabia pipe racks, pump stations, and outdoor MCCs. IP66 (protected against powerful water jets) is specified for enclosures exposed to wash-down, monsoon rain, or coastal spray — particularly on Jeddah and Yanbu coastal sites. IP67 (submersion to 1 metre for 30 minutes) is used in floor-mounted enclosures in water treatment plants and sump pump areas where temporary flooding is possible. All our GRP, stainless steel, and powder-coated steel enclosures are IP-rated and certified, with ATEX Zone 1/2 variants for hazardous areas.
Yes. Gulf Union Ozone stocks ATEX and IECEx certified explosion-proof enclosures for Zone 1 (Ex-d flameproof) and Zone 2 (Ex-e increased safety, Ex-nR restricted breathing) applications in Saudi Arabia oil and gas upstream, refinery, petrochemical, and gas processing plant environments. Ex-d (flameproof) GRP and cast aluminium junction boxes for Zone 1 — Group IIA, IIB, and IIC; T4/T5 temperature class; IP65 and IP66. Ex-e (increased safety) stainless steel and GRP enclosures for Zone 2 where terminations and passive components are housed. All ATEX/IECEx enclosures are supplied with full certification documentation — Ex certificate number, marking plate (Ex-d IIB T4 or equivalent), and wiring instructions. Contact us on WhatsApp 966550988062 with the hazardous area classification and application.
Gulf Union Ozone stocks GRP (glass-reinforced polyester) fibreglass junction boxes in the following standard sizes: 80×80×55mm (small field junction box), 150×110×70mm, 200×150×80mm, 300×200×100mm, 400×300×150mm, 500×400×200mm (large multi-cable JB), and 600×500×200mm (marshalling box). All GRP boxes are IP65 as standard (IP66 on larger sizes), RAL 7032 pebble-grey, with stainless steel 316L screws, removable gland plates, and earth stud. Transparent or opaque polycarbonate lid versions also stocked. GRP is the preferred material for Saudi Arabia coastal and corrosive environments — non-corroding, non-magnetic, lighter than steel, and UV-stable. Contact us on WhatsApp 966550988062 with your required size and quantity for an immediate quotation from Jeddah stock.
To get a fast quotation, provide: enclosure type (GRP / SS 316L / steel / ATEX), size (H×W×D mm), protection class (IP65/IP66/IP67), quantity, and delivery location in Saudi Arabia. For ATEX units, include the hazardous area zone (Zone 1 or Zone 2) and gas group (IIA/IIB/IIC).
Recent Deliveries
CR 4030570569 | ISO 9001:2015 | Jeddah, Saudi Arabia — Saudi Aramco vendor compliance · SAEP-347 credentials
Technical content reviewed by Gulf Union Ozone’s Engineering Team, Jeddah — 2026
Inventory updated: August 2026
Gulf Union Ozone Trading Co. supplies Electrical Enclosures & Junction Boxes to industrial customers across Saudi Arabia with delivery from our Jeddah warehouse — all products ship with original certificates and compliance documentation for Aramco, SABIC, and government projects.
Electrical Enclosures & Junction Boxes from Gulf Union Ozone serves Saudi Aramco operations, SABIC, SADARA, SEC utilities, NEOM mega-projects, and major industrial facilities across the Kingdom — our inventory covers the most common specifications and ratings.
Gulf Union Ozone stocks a comprehensive range of Electrical Enclosures & Junction Boxes — contact us for immediate availability confirmation and a competitive quotation with full compliance documentation and MTC traceability.
For urgent Electrical Enclosures & Junction Boxes procurement in Saudi Arabia, WhatsApp +966 55 098 8062 — our team confirms stock availability within the hour and provides competitive quotations with full compliance documentation for all industrial sectors.