Gulf Union Ozone supplies a comprehensive range of uninterruptible power supply systems and industrial batteries for critical power protection across Saudi Arabia. Our inventory covers online double-conversion UPS systems (1kVA–800kVA, VFI-SS-111 IEC 62040-3), modular scalable UPS platforms, VRLA sealed lead-acid batteries (AGM and GEL to IEC 60896-21/22), lithium iron phosphate (LiFePO4) battery systems, battery management systems (BMS), and industrial battery chargers — for data centres, control rooms, process instrumentation, SCADA systems, oil and gas facilities, and telecoms infrastructure throughout Saudi Arabia. ISO 9001:2015 certified (CR 4030570569). Same-day dispatch from our Jeddah warehouse.

Gulf Union Ozone carries six UPS and industrial battery product families to internationally recognised IEC and SASO standards, with manufacturer documentation and compliance certificates for every shipment.
Online double-conversion UPS systems to IEC 62040-3 VFI-SS-111 classification — zero millisecond transfer time, continuous double conversion of input AC→DC→AC for complete electrical isolation from mains disturbances. Single-phase output range 1kVA to 20kVA; three-phase 10kVA to 800kVA tower and rack-mount configurations. Input power factor correction (PFC) to 0.99, output power factor 0.9. Automatic voltage regulation (AVR), bypass switch, and dry-contact alarm outputs standard. Used in data centres, SCADA control rooms, medical facilities, and process control systems across Saudi Arabia oil and gas plants. SASO certified for KSA market. Input voltage range 110V–300V (single), 320V–480V (three-phase).
Hot-swap modular UPS platforms in 10kW–50kW power module increments scalable to 800kW total capacity — N+1 redundant configuration eliminates single points of failure. Modular design allows capacity expansion without shutdown. Power modules individually replaceable under load in under 5 minutes. Efficiency up to 96.5% online / 99% ECO mode. LCD touchscreen with RS232/RS485 Modbus, SNMP (dry contact) for building management system (BMS) integration. Battery cabinet expandable for 4h to 8h runtime at full load. Ideal for growing data centres, industrial control buildings, and telecom exchanges in Saudi Arabia where future load growth is planned.
Valve-regulated lead-acid (VRLA) batteries with absorbent glass mat (AGM) technology to IEC 60896-21 — sealed, maintenance-free, spill-proof for installation in any orientation. Available in 12V monobloc blocks (7Ah, 12Ah, 18Ah, 26Ah, 38Ah, 65Ah, 100Ah, 150Ah, 200Ah) and 2V flat-plate cells (100Ah to 3000Ah) for large battery rooms. Design life 5 years (standard) and 10–12 years (long-life/front access terminal). Ambient temperature range -15°C to +50°C; optimum 20–25°C. Compatible with all major UPS brands for replacement battery cartridges in Saudi Arabia data centres, substations, and control rooms. Float voltage 13.5–13.8V (12V block).
GEL electrolyte VRLA batteries to IEC 60896-21 — thixotropic silica gel immobilises electrolyte, eliminating stratification and providing superior deep-discharge recovery versus AGM. 12V blocks 65Ah–200Ah and 2V OPzV tubular-plate gel cells 200Ah–3000Ah for cyclic-duty solar UPS, telecom base stations, and substation DC systems. OPzV tubular positive plate design rated 1500+ partial cycles at 80% depth of discharge — suited to frequent mains outage environments in remote Saudi Arabia sites. Design life 15–20 years (2V OPzV). Suitable for outdoor telecom cabinets (IP55 enclosures) up to 50°C. Supplied with battery racks and inter-cell connectors for complete battery string assembly.
LiFePO4 battery modules in 48V (50Ah, 100Ah) and 192V (50Ah, 100Ah) rack-mount form for industrial UPS, energy storage systems (ESS), and critical power backup. Integrated battery management system (BMS) with cell-level monitoring, state-of-charge (SoC), state-of-health (SoH), temperature control, and overcharge/over-discharge/short-circuit protection. RS485 Modbus and CAN communication for UPS and SCADA integration. Cycle life 3000–6000 cycles at 80% DoD — 5–10 times longer than VRLA. Weight 60–70% lighter than equivalent lead-acid capacity. Operating temperature -20°C to +60°C. Used in new data centre UPS retrofits and solar energy storage projects across Saudi Arabia.
Battery management systems (BMS) for lithium battery banks — cell-level voltage and temperature monitoring, active/passive balancing, State-of-Charge (SoC) and State-of-Health (SoH) algorithms, RS485 Modbus / CAN / Ethernet communication, dry-contact alarm relay, and DIN-rail or rack-mount enclosures. Industrial battery chargers for VRLA and lithium chemistries: output voltages 24VDC, 48VDC, 110VDC, 220VDC; current ratings 5A to 100A; automatic IUoU charging profile with temperature compensation. IEC 60364 and EN 61558 compliant. Three-phase input available for high-current substation chargers. Used in substation DC systems, UPS bypass chargers, telecom rectifiers, and motor control centres throughout Saudi Arabia.
All UPS and battery systems supplied with manufacturer documentation and compliance certificates. IEC test reports and SASO certificates supplied with every order. ISO 9001:2015 QMS (CR 4030570569).
| Product | Standard / Spec | Material | Capacity / Rating | Application |
|---|---|---|---|---|
| Online Double-Conversion UPS — 1kVA–3kVA (Single Phase) | IEC 62040-3 VFI-SS-111 / SASO | Steel cabinet, copper busbars | 1kVA, 2kVA, 3kVA — 0.9PF output | Server rooms, network switches, CCTV and access control in KSA |
| Online Double-Conversion UPS — 6kVA–20kVA (Single Phase) | IEC 62040-3 VFI-SS-111 / IEC 62040-1 | Steel cabinet, IGBT inverter | 6kVA, 10kVA, 15kVA, 20kVA | Medical imaging, telecom racks, industrial PCs, lab instruments |
| Online Double-Conversion UPS — 10kVA–80kVA (Three Phase) | IEC 62040-3 VFI-SS-111 | Three-phase steel cabinet, DSP control | 10kVA to 80kVA, 400VAC 3-phase | Data hall UPS, process control buildings, industrial drives |
| Online Double-Conversion UPS — 100kVA–800kVA (Three Phase) | IEC 62040-3 VFI-SS-111 | Free-standing steel cabinet, transformer-based or transformerless | 100kVA to 800kVA | Large data centres, hospital critical buses, substation control power |
| Modular UPS Platform — 10kW Hot-Swap Module | IEC 62040-3 VFI-SS-111 | Aluminium chassis, hot-plug module, 400VAC | 10kW per module; up to 800kW in frame | Scalable data centre power, N+1 redundancy systems |
| Modular UPS — 30kW–50kW Power Module | IEC 62040-3 VFI-SS-111 | Steel modular rack, DSP IGBT | 30kW or 50kW per module | Large rack hall, telecoms exchange, industrial control buildings |
| VRLA AGM Battery — 12V 7Ah to 26Ah (Monobloc) | IEC 60896-21 / BS 6290-4 | ABS case, AGM separator, Pb-Ca grid | 12V / 7Ah, 12Ah, 17Ah, 26Ah | Small UPS battery cartridge replacement — offices, network rooms KSA |
| VRLA AGM Battery — 12V 38Ah to 65Ah (Monobloc) | IEC 60896-21 | ABS case, low antimony Pb grid, AGM | 12V / 38Ah, 45Ah, 65Ah | Mid-size UPS, telecom rectifier backup, security systems |
| VRLA AGM Battery — 12V 100Ah to 200Ah (Monobloc) | IEC 60896-21 | ABS case, large AGM monobloc | 12V / 100Ah, 120Ah, 150Ah, 200Ah | Large UPS string, industrial control room backup, emergency lighting |
| VRLA AGM Battery — 2V Cell 100Ah to 500Ah | IEC 60896-21 | Transparent PP case, 2V flat-plate cell | 2V / 100Ah, 200Ah, 300Ah, 500Ah | Substation battery room, large UPS systems in data centres KSA |
| VRLA AGM Battery — 2V Cell 600Ah to 3000Ah (Long-Life) | IEC 60896-21 / IEC 60896-22 | PP case, reinforced grid, 10–12 yr design life | 2V / 600Ah, 800Ah, 1000Ah, 1500Ah, 2000Ah, 3000Ah | Power utility substation, large industrial UPS battery rooms |
| VRLA GEL Battery — 12V 65Ah to 200Ah | IEC 60896-21 | ABS case, silica gel electrolyte | 12V / 65Ah, 100Ah, 150Ah, 200Ah | Cyclic UPS duty, solar battery bank, telecom base stations KSA |
| OPzV Tubular GEL Battery — 2V 200Ah to 1000Ah | IEC 60896-21 | Transparent PP, tubular positive plate, gel | 2V / 200Ah, 300Ah, 400Ah, 600Ah, 800Ah, 1000Ah | Telecom tower, solar-diesel hybrid, remote Saudi Arabia site backup |
| OPzV Tubular GEL Battery — 2V 1200Ah to 3000Ah (Heavy Duty) | IEC 60896-21 | PP jar, tubular plate, 15–20 yr design life | 2V / 1200Ah, 1500Ah, 2000Ah, 3000Ah | Utility substation, large-scale renewable energy storage KSA |
| LiFePO4 Battery Module — 48V 50Ah (Rack Mount) | IEC 62619 / UN38.3 | Lithium iron phosphate prismatic cells, aluminium frame | 48V / 50Ah (2.4kWh) | UPS runtime extension, data centre battery cabinet, ESS modules |
| LiFePO4 Battery Module — 48V 100Ah (Rack Mount) | IEC 62619 / UN38.3 | LiFePO4 prismatic, integrated BMS | 48V / 100Ah (4.8kWh) | High-density UPS battery shelf, telecom DC power, industrial backup |
| LiFePO4 Battery Module — 192V 50Ah | IEC 62619 | LiFePO4 cells in series, BMS protection | 192V / 50Ah (9.6kWh) | Medium UPS battery replacement, industrial inverter ESS |
| LiFePO4 Battery Module — 192V 100Ah | IEC 62619 | LiFePO4 prismatic, CAN/RS485 BMS | 192V / 100Ah (19.2kWh) | Large UPS battery replacement, commercial energy storage KSA |
| Battery Management System (BMS) — 48V Lithium | IEC 62133, RS485 Modbus | PCB in ABS or DIN-rail enclosure | 48V 16-cell BMS; up to 400A continuous | Cell monitoring, SoC/SoH, protection relay for 48V Li banks |
| Battery Management System (BMS) — 192V–384V High Voltage | IEC 62133, CAN / Ethernet | Steel DIN-rail master-slave BMS | Up to 384V / 600A | Industrial ESS, large UPS Li battery string management |
| Industrial Battery Charger — 24VDC / 48VDC Output | IEC 60364 / EN 61558 | Steel DIN-rail enclosure, SMPS topology | 24V or 48V / 5A–50A | Control room DC supply, substation 48V charging, VRLA float charging |
| Industrial Battery Charger — 110VDC Output | IEC 60364, IUoU profile | Steel panel-mount, three-phase input | 110VDC / 20A–100A | Substation DC bus charging, switchgear trip coil backup |
| Industrial Battery Charger — 220VDC Output | IEC 60364, temp. compensated | Steel panel-mount, SCR or SMPS | 220VDC / 20A–100A | HV substation DC systems, industrial bypass charger |
| Static Transfer Switch (STS) — 10kVA–160kVA | IEC 62040-3 | Steel cabinet, thyristor-based | 10kVA, 20kVA, 40kVA, 80kVA, 160kVA — <1ms transfer | Dual-feed server load switchover, redundant UPS tie-in |
| UPS Bypass Panel — Manual Maintenance Bypass | IEC 62040 | Steel enclosure, copper busbar, isolators | 10kVA to 800kVA | Maintenance bypass for online UPS servicing without load interruption |
| Battery Cabinet — UPS Extended Runtime | IEC 62040 | Powder-coat steel, cable bushing, ventilated | Suits 12V or 2V VRLA strings; up to 1500Ah total | Extended battery runtime enclosures for VRLA UPS strings |
| Battery Rack — 2-Tier / 4-Tier Steel | EN 60298 / seismic bracing option | Hot-dip galvanised steel | For 2V cells 200Ah–3000Ah; up to 48-cell strings | Substation battery room, large UPS installation Saudi Arabia |
| UPS Monitoring & SNMP Card | SNMP v1/v2c/v3, Modbus RTU/TCP | PCB slot card, RJ45 / RS485 | Plug-in card for rack UPS 1kVA–800kVA | Remote UPS monitoring via BMS/DCIM, alarm on email/SNMP trap |
We understand the IEC 62040 VFI-SS-111 classification requirements for zero-transfer-time UPS and supply correctly rated systems for Saudi Arabia oil and gas control rooms, data centres, and process instrumentation. SASO certification verified before supply.
Battery certificates, UPS factory acceptance test (FAT) reports, IEC compliance datasheets, and SASO certificates supplied with every order. EN 10204 2.2 test reports available for batteries on request.
Gulf Union Ozone is ISO 9001:2015 certified (CR 4030570569), Jeddah — incoming inspection and traceability on all UPS and battery stock.
Delivery to all 18 Saudi regions — Jeddah, Riyadh, Dammam, Jubail, Yanbu, Jizan, Tabuk and beyond. Stocked UPS units dispatched same-day.
Self-regulating and constant-wattage heat trace cables, MI cables, and control panels for freeze protection and process temperature maintenance in Saudi Arabia.
Cable trays, conduit systems, cable ladders, and wire management products for electrical installations across Saudi Arabia industrial sites.
Air, hydraulic, and liquid filter elements for protecting process equipment and maintaining air quality in industrial facilities in Saudi Arabia.
PPE, fall protection, gas detection, and industrial safety supplies for maintenance and construction work in Saudi Arabia facilities.
Gulf Union Ozone supplies online double-conversion UPS systems classified VFI-SS-111 per IEC 62040-3 — the highest availability classification for zero-transfer-time critical power. Our range covers 1kVA to 800kVA single-phase and three-phase systems from leading brands for data centres, control rooms, SCADA systems, and process instrumentation in Saudi Arabia. We also stock modular UPS platforms with hot-swap power modules in 10kW–50kW increments scalable to 800kW. All UPS systems are SASO certified for Saudi Arabia market. Same-day dispatch from Jeddah warehouse for stocked units. Contact us via WhatsApp 966550988062.
Yes. Gulf Union Ozone stocks VRLA sealed lead-acid batteries in both AGM (absorbent glass mat) and GEL designs to IEC 60896-21/22, available in 12V blocks from 7Ah to 200Ah and 2V cells from 100Ah to 3000Ah for UPS battery cabinets, telecom rectifiers, and standby power systems. Lithium iron phosphate (LiFePO4) batteries with integrated BMS are available in 48V–192V rack-mount formats for extended runtime UPS applications and energy storage in Saudi Arabia data centres and industrial facilities. All batteries supplied with manufacturer datasheets and test certificates.
Yes. Gulf Union Ozone supplies battery management systems (BMS) for lithium battery banks with cell-level monitoring, state-of-charge (SoC) estimation, overcharge/over-discharge protection, and RS485/CAN communication for SCADA integration. Industrial battery chargers in 24V, 48V, 110V, and 220V DC output voltages are stocked for lead-acid and lithium chemistries. Automatic equalization charging, temperature compensation, and IEC 60364 compliance. Used in substations, industrial UPS bypass, telecom, and oil and gas control facilities across Saudi Arabia. Contact us on WhatsApp 966550988062 or email info@gulfunionozone.com.
To get a fast quotation, provide: UPS power rating (kVA) or battery capacity (Ah / voltage), technology (VRLA AGM, GEL, LiFePO4), application (UPS, substation, telecom), required runtime at full load, and delivery location in Saudi Arabia.
Recent Deliveries
CR 4030570569 | ISO 9001:2015 | Jeddah, Saudi Arabia — Saudi Aramco vendor compliance · SAEP-347 credentials
Technical content reviewed by Gulf Union Ozone’s Engineering Team, Jeddah — 2026
Inventory updated: August 2026
Gulf Union Ozone Trading Co. supplies UPS & Industrial Battery Systems to industrial customers across Saudi Arabia with delivery from our Jeddah warehouse — all products ship with original certificates and compliance documentation for Aramco, SABIC, and government projects.
UPS & Industrial Battery Systems from Gulf Union Ozone serves Saudi Aramco operations, SABIC, SADARA, SEC utilities, NEOM mega-projects, and major industrial facilities across the Kingdom — our inventory covers the most common specifications and grades.
Gulf Union Ozone stocks a comprehensive range of UPS & Industrial Battery Systems — contact us for immediate availability confirmation and a competitive quotation with full compliance documentation.
For urgent UPS & Industrial Battery Systems procurement in Saudi Arabia, WhatsApp +966 55 098 8062 — our team confirms stock availability within the hour and provides competitive quotations for Aramco, SABIC, SEC, and government projects.